MATRIX MDM-8145A/MDM-8146A линейка цифровых мультиметров
- Описание
-
Описание
-
Mode
MDM8145A
Display digits
22000(4½)
Maximum measurement speed
7 times / sec
Function
DC voltage
DC current
AC voltage
AC current
Accuracy
±(0.05%+3)
±(0.35%+10)
±(0.8%+80)
±(0.8%+80)
Range
10uV~1000V
10nA~10A
10uV~750V
10nA~10A
Highest resolution
10uV
10nA
10uV
10nA
--
40Hz~100kHz
40Hz~10kHz
Function
Resistance
Capacitance
Frequence
Period
Accuracy
±(0.1%+6)
±(3.5%+30)
±(0.2%+10)
±(0.2%+10)
Range
10mΩ~200MΩ
1pF~10mF
1Hz~20MHz
50ns~500ms
Highest resolution
10mΩ
1pF
0.001Hz
0.01ns
Others
Mathematical functions
MX+B/MAX/MIN/dB/dBm/Rel/Comp Hi/Comp Low/Hold/Statistics
Resistance measurement
Support 2-wire, 4-wire in two ways.
Continuity test
When the resistance is less than 30 ohms, the buzzer sounds.
Diode test
Measurable range: 0~2V
AC+DC measurement
Support.
Trigger mode
Standard: automatic trigger, single trigger; Optional: external trigger.
Duty cycle measurement
5.0%~95.0%. (the error is within 10 words.)
Square wave output
Frequence: 1Hz~100kHz, amplitude: 3V.(Optional.)
Limit test
Support.
Calibration
Support.
Temperature
Thermocouple: K/N/R/S/T/B/E/J/WRe325/WRe526; RTD: PT100/PT50/Cu100/ Cu50.
Communication Interface
Standard: USB Device; Optional: USB Host, RS232, GPIB, LAN, WIFI, Bluetooth.
Additional functions
Data hold, data record, data readback.
Mode
MDM8146
Display digits
22000(4½)
Maximum measurement speed
7 times / sec
Function
DC voltage
DC current
AC voltage
AC current
Accuracy
±(0.02%+3)
±(0.1%+3)
±(0.2%+20)
±(0.3%+3)
Range
10uV~1100V
10nA~12A
10uV~800V
10nA~12A
Highest resolution
10uV
10nA
10uV
10nA
--
40Hz~100kHz
40Hz~10kHz
Function
Resistance
Capacitance
Frequence
Period
Accuracy
±(0.05%+5)
±(2%+5)
±(0.05%+3)
±(0.05%+3)
Range
10mΩ~1GΩ
1pF~10mF
1Hz~20MHz
50ns~500ms
Highest resolution
10mΩ
1pF
0.001Hz
0.01ns
Others
Mathematical functions
MX+B/MAX/MIN/dB/dBm/Rel/Comp Hi/Comp Low/Hold/Statistics
Resistance measurement
Support 2-wire, 4-wire in two ways.
Continuity test
When the resistance is less than 30 ohms, the buzzer sounds.
Diode test
Measurable range: 0~2V
AC+DC measurement
Support.
Trigger mode
Standard: automatic trigger, single trigger; Optional: external trigger.
Duty cycle measurement
5.0%~95.0%. (the error is within 10 words.)
Square wave output
Frequence: 1Hz~100kHz, amplitude: 3V.(Optional.)
Limit test
Support.
Calibration
Support.
Graphic display
Trend chart, Histogram, Bar Meter.
Customized sensor
Users can customize the relationship curve, through the USB communication port or U disk to download, support up to 20 kinds.
Temperature
Thermocouple: K/N/R/S/T/B/E/J/WRe325/WRe526; RTD: PT100/PT50/Cu100/ Cu50.
Communication Interface
Standard: USB Device; Optional: USB Host, RS232, GPIB, LAN, WIFI, Bluetooth.
Additional functions
Data hold, data record, data readback.
-
















































































































































.jpg)